A digital gauss meter (also called a tesla meter or gaussmeter) that measures magnetic field strength and shows the reading in gauss or tesla. It also checks polarity. The unit is small, light and easy to operate, so it can be carried to the production line.

You cannot tell by looking whether a magnet is as strong as it was. A bar that has run for years looks the same as a new one. A gauss meter gives you a number you can record and compare later.

What a gauss meter is used for

  • Checking magnetic separators in food and pharmaceutical lines, such as magnetic bars and lattice magnets, against their rated strength. ICL magnet bars come in 10,000, 11,000 and 12,000 gauss.
  • Inspecting a new batch of magnets against the order before assembly or installation.
  • Testing steel parts for residual magnetism. A part that holds residual magnetism picks up steel chips.
  • Recording a reference value for each magnet on the day it is installed, to compare at the next check.

How to measure gauss so readings can be compared

The reading changes with the position, distance and angle of the probe. The further from the magnet surface, the lower the value. Two readings are comparable only when they are taken the same way.

  1. Pick the measuring points on each magnet and mark or note them.
  2. Hold the probe flat on the surface at that point, in the same orientation each time.
  3. Use the same meter and the same probe.
  4. Record the first reading while the magnet is new. That is its reference value.
  5. Measure again at the interval your quality plan sets, and compare with the reference.

A permanent magnet can lose strength when it is heated above the working temperature of its grade, so lines that run hot product should be checked more often.

How many gauss in one tesla

One tesla equals 10,000 gauss. A magnet rated at 12,000 gauss is 1.2 tesla. If the meter shows millitesla (mT), multiply by 10 to get gauss.

Does a reading below the spec mean the magnet has weakened?

It may or may not. The spec value and your reading may have been taken at a different point, a different distance or with a different probe. Compare with the reading you took when the magnet was new, using the same meter. If the value keeps falling, send a photo of the magnet and your readings to sales@iclmagnet.com.

Gauss meter price

ICL magnet does not list prices on the website. Ask for a quote by LINE @iclmagnet or sales@iclmagnet.com. Three details speed up the reply:

  • The kind of magnet you will measure, for example magnetic bars, lifting magnets or finished parts
  • The approximate gauss value on that magnet’s spec
  • The number of meters you need

Can ICL magnet measure for us instead?

Yes. ICL magnet inspects magnets, measures their strength and issues a report. See our services.

If you only need to know north from south, see the Pole Identifier. To see the whole pole pattern at once, see the Pole Test Viewer.

Ask about models, measuring range or a quote on LINE @iclmagnet, call 02-750-9444 or email sales@iclmagnet.com.

Lifting Magnet Permanent Magnet แม่เหล็ก
Menu
จำหน่ายแม่เหล็กครบวงจร
  • ศูนย์รวมแม่เหล็ก ถาวร แม่เหล็กขนาดใหญ่
Gauss / Tesla Meter
Gauss / Tesla Meter A digital gauss meter (also called a tesla meter or gaussmeter) that measures magnetic field strength and shows the reading in gauss or tesla. It also checks polarity. The unit is small, light and easy to operate, so it can be carried to the production line. You cannot tell by looking whether a magnet is as strong as it was. A bar that has run for years looks the same as a new one. A gauss meter gives you a number you can record and compare later. What a gauss meter is used for Checking magnetic separators in food and pharmaceutical lines, such as magnetic bars and lattice magnets, against their rated strength. ICL magnet bars come in 10,000, 11,000 and 12,000 gauss. Inspecting a new batch of magnets against the order before assembly or installation. Testing steel parts for residual magnetism. A part that holds residual magnetism picks up steel chips. Recording a reference value for each magnet on the day it is installed, to compare at the next check. How to measure gauss so readings can be compared The reading changes with the position, distance and angle of the probe. The further from the magnet surface, the lower the value. Two readings are comparable only when they are taken the same way. Pick the measuring points on each magnet and mark or note them. Hold the probe flat on the surface at that point, in the same orientation each time. Use the same meter and the same probe. Record the first reading while the magnet is new. That is its reference value. Measure again at the interval your quality plan sets, and compare with the reference. A permanent magnet can lose strength when it is heated above the working temperature of its grade, so lines that run hot product should be checked more often. How many gauss in one tesla One tesla equals 10,000 gauss. A magnet rated at 12,000 gauss is 1.2 tesla. If the meter shows millitesla (mT), multiply by 10 to get gauss. Does a reading below the spec mean the magnet has weakened? It may or may not. The spec value and your reading may have been taken at a different point, a different distance or with a different probe. Compare with the reading you took when the magnet was new, using the same meter. If the value keeps falling, send a photo of the magnet and your readings to sales@iclmagnet.com. Gauss meter price ICL magnet does not list prices on the website. Ask for a quote by LINE @iclmagnet or sales@iclmagnet.com. Three details speed up the reply: The kind of magnet you will measure, for example magnetic bars, lifting magnets or finished parts The approximate gauss value on that magnet’s spec The number of meters you need Can ICL magnet measure for us instead? Yes. ICL magnet inspects magnets, measures their strength and issues a report. See our services. If you only need to know north from south, see the Pole Identifier. To see the whole pole pattern at once, see the Pole Test Viewer. Ask about models, measuring range or a quote on LINE @iclmagnet, call 02-750-9444 or email sales@iclmagnet.com.